Cost

Home

Coil, Condenser Alexander

May 2015

For upstairs system: Carrier 5 ton condenser, horizontal evaporator coil, run additional duct to bedroom, PTRAP, float switch, hard start, replace breaker and pad. Mastic seal plenum, flush line set and check high and low voltage.

Alexander, AR

Condenser, Furnace and Evaporator Coil Hot Springs

Mar 2012

Trane 3 ton condenser, furnace and evaporator coil. Flushed line set, installed filter drier, moved condenser to the right, relcoated safety disconnect, mastic seal supply plenum, installed filter rack and thermostat.

Hot Springs, AR

Heat Pump, Air Handler Hot Springs

Feb 2012

Trane 4 ton heat pump, air handler and heat strips. Flushed line set, mastic sealed supply and return plenum and reconfigure condenser drain. Installed digital thermostat and filter drier.

Hot Springs, AR

Little Rock- Furnace Install

Feb 2012

Trane horizontal VSP furnace. Make sure flue has proper rise and is sealed properly. Installed new gas flex, safety pan and float switch. Make sure drain lines have proper fall and mastic seal plenum.

Little Rock, AR

Furnace, Coil, Condenser - Little Rock

Dec 2011

Trane 2.5 ton upflow furnace, evaporator coil, condenser, line set, 24x12 filter grill, gas flex, filter drier, digital thermostat, whip combustion air, condensate pump and drain lines.

Little Rock, AR

Furnace Installation - Little Rock

Dec 2011

Trane upflow furnace, gas flex 5" to 4" reducer for flue with 4" connections, combustion air and mastic seal supply plenum.

Little Rock, AR

Furnace Installation - Little Rock

Dec 2011

Carrier 2 stage furnace for downstairs system, thermostat, gas flex, high and low voltage, 2x4 box with light switch, vent motor, flue pipe and brush evaporator coil.

Little Rock, AR

North Little Rock Package Unit Install

Dec 2011

Trane 3 ton package unit. New return air pipe 16", 20x25 rag grill, drain line, spot ins, digital thermostat, SQ to round duct to connect, run hard pipe off of existing copper, seal tran, seal & insulate return air pipe.

North Little Rock, AR

Maumelle, Ar -Furnace Installation

Dec 2011

Lennox upflow furnace, filter rack, thermostat, brush & seal around evaporator coil, gas flex, vacuum platform & return air box, flue connects, check high and low voltage.

Maumelle, AR